Abilene (325) 668-2226
Progressing Cavity Pump Services

Abilene Local

Progressing Cavity Pump Services

From system design through failure analysis. Every service Richardson Pump Service performs is focused on artificial lift.

Request an estimate

Tell us what you need

No obligation


By submitting this form you agree that we may contact you about your request and share your name and email address with partner companies for email marketing. We never share your mobile number or text message consent with third parties or affiliates for marketing or promotional purposes.

Artificial Lift Services for Oil & Gas Operators

Richardson Pump Service has specialized in Progressing Cavity Pump systems since 1985. Every service listed here is performed by technicians who work exclusively in artificial lift, not a general pump shop that handles oilfield work on the side. Operators across Sweetwater, Big Spring, and the wider Permian Basin region have relied on this team for downhole pump selection, surface drive installation, workover response, and parts supply.

Sam Richardson built this business around one discipline. The result is a depth of PCP-specific knowledge that shows up in the field, in pump sizing decisions, elastomer selection for high-temperature or high-gas wells, and in failure analysis that identifies root cause rather than just replacing equipment.

PCP System Design & Installation

Pump selection and system configuration sized to your actual well conditions.

We engineer and install complete Progressing Cavity Pump systems tailored to your well conditions. Our team evaluates fluid properties, production targets, and downhole parameters to select the right pump, motor, and drive system for maximum run life and production efficiency. We work across all major PCP brands, PCM, Artemis, Weatherford, and SLB - Oil Lift, so the recommendation is driven by the well, not by what's on a shelf.

  • Custom pump selection and sizing
  • Surface drive unit installation
  • Downhole pump and rod string assembly
  • Variable speed drive (VSD) integration
  • Production optimization consulting
wellhead assembly work, illustration in Abilene, TX

Field Maintenance & Workover

Scheduled programs and emergency response, the same technical team for both.

Keeping an artificial lift system at peak performance requires service that moves as fast as the problem. Our field technicians are experienced with all major PCP brands and understand the difference between a minor tuning issue and a failure event developing underground. We run scheduled preventive programs to extend run life, and we respond to emergency workovers with the same crew, no handoff to a subcontractor. Operators near Clyde, Merkel, and throughout West Texas know they can reach Sam directly when a well goes down.

stuffing box polish rod work, illustration in Abilene, TX

Wellhead & Surface Equipment

Sealed, controlled, and producing, surface configuration done by PCP specialists.

Wellhead Assembly

Installation and commissioning of complete wellhead packages configured for PCP operation, including polish rod guides and stuffing box alignment.

Stuffing Box & Polish Rod

Routine packing service and emergency stuffing box replacement to stop surface leaks before they become environmental and safety incidents.

Torque Anchors & Centralizers

Supply and installation of downhole anchoring systems that protect the rod string and maintain concentricity through the pump.

Pressure Control Equipment

Safety valves, chokes, and pressure gauges installed and tested to keep surface systems within operating parameters and in regulatory compliance.

  • Wellhead assembly and installation
  • Stuffing box and polish rod service
  • Torque anchor and centralizer supply
  • Flowline and production vessel connections
  • Safety valve and pressure control equipment

Parts & Support

Parts Supply & Technical Support

Stator-to-sheave inventory on hand, no waiting on freight to restart a well.

We stock a broad inventory of PCP components and consumables so operators can get what they need without long lead times. Our technical team is available to help identify the right part, confirm compatibility, and troubleshoot system issues, whether the problem is a worn elastomer, an undersized sheave, or a coupling failure. Parts availability through our gallery of stocked equipment reflects 40 years of knowing what fails and when.

  • Stators, rotors, and elastomer components
  • Drive heads, belts, and sheaves
  • Rod guides, couplings, and centralizers
  • Stuffing boxes and packing assemblies
  • Technical consultation and troubleshooting

Wellhead Drive, Automation & VFD Controls

SPOC and NETCO drive systems, variable frequency control, and automation retrofits.

Variable frequency drives extend PCP run life by matching surface torque to downhole conditions in real time, reducing startup stress, preventing overtorque failures, and enabling remote speed adjustment as fluid levels and viscosities shift. We supply and commission drive systems from SPOC and NETCO and can retrofit automation controls onto existing installations. Operators near Buffalo Gap and Cross Plains working mature wells with changing fluid profiles have seen measurable run-life improvement after VFD retrofits.

pressure control equipment work, illustration in Abilene, TX

Fluid Level Services

Acoustic fluid level measurement that informs pump sizing and operational decisions.

Acoustic Fluid Level Measurement

Precise downhole fluid level determination using acoustic pulse technology, identifies pump submergence and gas interference without pulling the pump.

Production Diagnostics

Fluid level data combined with surface production rates to identify whether a well is pump-limited, reservoir-limited, or operating at the wrong speed.

Pump Sizing Confirmation

Pre-installation and post-installation fluid level checks to confirm that the selected pump is appropriately sized for actual inflow conditions.

Failure Analysis

Pump Failure Analysis

Understanding why a pump failed prevents paying for the same failure twice.

When a PCP fails prematurely, the most expensive response is to pull it, replace it, and run the same configuration. Root cause analysis, examining the rotor, stator, rod string, and operating history together, identifies whether failure came from fluid incompatibility, overtorque, gas interference, improper sizing, or a manufacturing defect. Richardson Pump Service performs failure analysis as a standard part of the workover process, not an optional add-on. Operators near Ovalo and Tuscola working wells with repeat failures have used this process to break the cycle.

torque anchors centralizers work, illustration in Abilene, TX

Talk to a PCP Specialist

Direct line to Sam

(325) 668-2226

Based in Abilene, TX

Frequently asked questions

Question not here?(325) 668-2226

Ask Sam directly.

Does Richardson Pump Service only work on progressing cavity pumps?
Yes. RPS has specialized in Progressing Cavity Pump systems and artificial lift since 1985. The technicians who design, install, and service your system work exclusively in artificial lift, not as a general pump shop that takes oilfield work on the side.
Do you respond to emergency workovers?
Yes. Alongside scheduled preventive maintenance programs, RPS responds to emergency workovers with the same field crew, with no handoff to a subcontractor. Call Sam directly at (325) 668-2226 when a well goes down.
Do you stock PCP parts and surface equipment?
RPS carries a broad inventory of PCP components, consumables, and wellhead parts for common configurations, so operators avoid long lead times. The technical team can help confirm compatibility and troubleshoot issues such as worn elastomers, undersized sheaves, or coupling failures.
Can you retrofit a VFD onto an existing PCP installation?
Yes. RPS supplies and commissions SPOC and NETCO drive systems and can retrofit automation controls onto existing installations. Matching surface torque to downhole conditions reduces startup stress and helps prevent overtorque failures.
Why order failure analysis instead of just replacing the pump?
Replacing a failed PCP with the same configuration often repeats the failure. RPS examines the rotor, stator, rod string, and operating history together to identify whether the cause was fluid incompatibility, overtorque, gas interference, improper sizing, or a manufacturing defect, and performs this as a standard part of the workover process.

Next step

Tell us about the job

Your name, your number and what needs doing. A person from Richardson Pump Service Inc gets back to you.

Rather talk now?(325) 668-2226

No obligation


By submitting this form you agree that we may contact you about your request and share your name and email address with partner companies for email marketing. We never share your mobile number or text message consent with third parties or affiliates for marketing or promotional purposes.